Telecentric scanning lenses have special optical configurations,which enable an output beam perpendicular to the plat image plane.Due to the smallest possible spot size and highest possible power density,the telecentric scanning lenses are widely used in high-end laser applications.We provide telecentric scanning lenses with a higher performance ratio compared to world -famous optics companies.
Suitable for high-end laser application
355nm,532nm,1064nm Designed for 355nm,532nm,1064nm laser source
High damage threshold
2.1 355nm wavelength
Focal Length (mm) |
Working distance (mm) |
wavelength |
Scan field (mm) |
Scan Angle |
Incident Beam Ø[mm] |
Spot Size (µm) |
Outside Ø [mm] |
Mount Thread |
Max. Deviation |
110 |
153.867 |
355 |
Φ92 65*65 |
±24° |
8 |
11.9 |
Ø 120*86 |
M85×1 |
1.5 |
2.2 532nm wavelength
Focal Length (mm) |
Working distance (mm) |
wavelength |
Scan field (mm) |
Scan Angle |
Incident Beam Ø[mm] |
Spot Size (µm) |
Outside Ø [mm] |
Mount Thread |
Max. Deviation |
100 |
126.6 |
532 |
Φ77 54.5*54.5 |
±22° |
15 |
7 |
120*86.6 |
M85×1 |
2.3 |
102 |
132.94 |
532 |
Φ80 56*56 |
±23° |
18 |
6 |
120*63.1 |
M85×1 |
3.5 |
165 |
189.88 |
532 |
Φ144 101*101 |
±25° |
20 |
8 |
120 |
M85×1 |
4 |
170 |
214.66 |
532 |
Φ129 91*91 |
±21.8° |
14 |
11.6 |
140*108.7 |
M85×1 |
4 |
2.3 1064nm wavelength
Focal Length (mm) |
Working distance (mm) |
wavelength |
Scan field (mm) |
Scan Angle |
Incident Beam Ø[mm] |
Spot Size (µm) |
Outside Ø [mm] |
Mount Thread |
Max. Deviation |
100 |
122.8 |
1064 |
Φ77 54.5*54.5 |
±22° |
15 |
13 |
120 |
M85×1 |
2.1 |
125 |
139.57 |
1064 |
Φ109 77*77 |
±25° |
20 |
12 |
120 |
M85×1 |
3 |
167 |
215.2 |
1064 |
128.24 90.7*90.7 |
±22° |
25 |
13.24 |
140*108.7 |
M85×1 |
4.4 |
170 |
220.71 |
1064 |
Φ130.55 92*92 |
±22° |
30 |
11 |
140*108.7 |
M112*1 |
4.4 |